Study
found several effective ways to prevent LED street lamp damage from lighting.
1. External
lightning protection combined with internal lightning protection
Now
the general LED lights exterior are the conductor material which is equivalent
to a lightning rod, the design must
be installed deflectors and ground network, these systems constitute the
external lightning protection system. The
system can prevent LED street lights from fire and cause personal safety
incidents due to direct lightning. Internal
lightning protection system refers to the internal street through the ground,
set the voltage protection, and protection of equipment. The
system prevents lightning overvoltages and other forms of invasion, destruction
caused by the power, which is the external lightning protection system can’t be
guaranteed. Between the two are mutually
reinforcing and complementary. Internal
lightning protection systems in many devices such as housing, access to
protected areas and cable, metal pipes, etc. must be connected to the external
lightning protection system or set overvoltage protection, and equipotential
bonding.
2. Lightning
equipotential bonding
To
completely eliminate the damage caused by lightning of potential difference,
power lines, signal lines, metal pipes and so use overvoltage protection
equipotential bonding. Each inner
protection zone at the interface must also be local equipotential connection,
various local equipotential connection to connect to each other, and finally
connected with the main equipotential place.
3. Set
up lightning protection zone
LED
lights in addition to power supplies in current, it will also set up some
communication devices are used to control the lights off and the brightness, power
of these devices are to be resettled in the lightning protection zones,
protected areas directly affected by the Shell Shield. The
electromagnetic field is much weaker here.
4. High
quality protective equipment - Lightning and overvoltage protection module
SPD's role is in the
shortest time the system will be connected to the equipotential protection
systems, so that each port facilities is equal to the potential. While the circuit due to the enormous lightning pulse energy generated
by the short route released into the earth, reduce equipment side of the
potential difference between the interfaces, which play the role of protective
equipment.
No comments: